Sentinel Power

  • Input / Output: 1/1 Phase ON LINE, 3/1 Phase ON LINE
  • Rating: 5000-10000VA

Sentinel Power series includes;  5kVA-6kVA single/single phase and 6.5kVA-8kVA-10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage to your critical load.

Input and output filters increase the immunity of the load against mains power disturbances and lightning strikes.

Enquire about this product
ModelPower
SPW 50005000VA / 4000W
SPW 60006000VA / 4800W
SPT 65006500VA / 5200W
SPT 80008000VA / 6400W
SPT 10000100000VA / 8000W
Operating Mode (Selectable)Description
ECONOMY Mode

Allows you to select Line Interactive topology , increases operating efficiency to typically 98%.

FREQUENCY CONVERTER

System can be set for 50/60 or 60/50Hz

ON-LINE

Affords MAXIMUM protection to load (default).

SMART ACTIVE

The UPS automatically selects the operating mode based on mains power supply quality.

STANDBY-OFF

The UPS supplies the load only when the mains fails. The Inverter starts with a progressive start-up.

Sentinel Power series includes;  5kVA-6kVA single/single phase and 6.5kVA-8kVA-10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage to your critical load.

Sentinel Power input and output filters increase the immunity of the load against mains power disturbances and lightning strikes.

HIGH UPS RELIABILITY

  • Full microprocessor control.
  • No break static and maintenance bypass.
  • Features guaranteed up to 40°C (the components are designed to operate at high temperatures and thus are subject to less stress at ordinary temperatures).

SELECTABLE OPERATING MODES
The operating mode can be programmed using the software or selected manually on the digital front panel display.

  • Online Mode (VFI).
  • Economy Mode: increases efficiency (up to 98%), and uses Line Interactive (VI) technology to power low priority loads from the mains supply.
  • Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply.
  • Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode).
  • Frequency converter Mode (50 or 60 Hz).

HIGH-QUALITY OUTPUT VOLTAGE

  • With distorting loads (IT loads with a crest factor of up to 3:1).
  • High short circuit current on bypass.
  • High overload capacity: 150% on the inverter, even when mains power fails.
  • Filtered, stabilised and reliable voltage (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference).

SIMPLIFIED INSTALLATION

  • The UPS can be connected to both single phase and three phase mains supplies.
  • Output terminal board + 2 IEC plugs to power local equipment (computers, modems, etc.).
  • Easy to move thanks to built-in wheels.

HIGH BATTERY RELIABILITY

  • Automatic and manual battery tests.
  • Low Ripple Current Discharge system “LRCD” to prolong battery life.
  • Unlimited extendable runtime thanks to dedicated modular design Battery Boxes.
  • Increased ride-through for mains failures up to 40ms (high hold up time) and for fluctuations in the input current ranging from 84V to 276V).

LOW IMPACT ON MAINS POWER

Sinusoidal input current on single phase/single phase series.

OTHER FEATURES

  • Filtered, stabilised and reliable current (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference).
  • Advanced diagnostics: status, measurements and alarms available on the custom LCD display
  • Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter with high switching frequency
  • (>20kHz, value above the audible range)
  • Auto restart when mains power returns, can be programmed using software or the digital front panel display
  • Emergency mode: the UPS can be programmed to work only when mains power fails (suitable for emergency lighting)
  • Standard back feed protection: to avoid current being fed back into the mains system.
  • Digital updating of the UPS (flash upgradable)

ADVANCED COMMUNICATION

  • Compatible for use remote monitoring.
  • Advanced, multi-platform communication for all operating systems and network environments: PowerShield³ monitoring and shut-down software included, for Windows 2008, Vista, 2003, XP; Mac OS X,
  • Linux, Novell and most popular Unix operating systems.
  • RS232 serial port.
  • Plug and Play connection.
  • Slots for communication interface boards.

Sentinel Power is an on-line double-conversion UPS in accordance with VFI-SS-111.